Fire Control System

Fire Control System_Digilogic systems

Digilogic’s Fire Control System combines image acquisition and image processing with the closed-loop control system. From the field of view (FOW), an image will be captured by a camera link camera, processing will be done on the image using various techniques like filters, detection, etc., and control signals to the pointing system will be generated based on the results from the image processing. This system functions as a headless real-time system.

TECHNICAL SPECIFICATIONS:

DescriptionSpecifications
ProcessorIntel Xeon E5 or better
L3 cache≥ 20 MB
RAMDDR4, 8GB
Storage80 GB SSD
Peripherals2 x USB 3.0, 4 x USB 2.0, 2 x Gigabit Ethernet LAN, 1 x DisplayPort and 1 x SMB trigger.
2 x Cameralink Ports with each having following features:
• Clock Frequency: Shall support all camera link frequencies from 20 MHz to 85 MHz.
• Cameralink Interface: Cameralink Base, Medium & Full on 26Pin SDR Connector
• Data rate capability: 200px x 200px @ 1000 frames per second.
• Bit depths: 8bit, 10bit and 12bit.
1 x FPGA based Multifunction Data Acquisition Interface:
• FPGA type: Kintex-7 160T
• Number of flip-flops: 2,02,800
• Number of LUTs: 1,01,400
• Embedded Block RAM: 11,700 kbits
• Number of DSP48 slices: 600
• Timebase: 40 MHz, 80 MHz, 120 MHz, 160 MHz, or 200 MHz
• Default timebase: 40 MHz
• Timebase reference source: PXI Express 100 MHz (PXIe_CLK100)
• ADC: 8 Channels, Configurable as Differential/Single Ended
• Type of ADC: Successive Approximation Register (SAR)
• ADC Resolution: 16 bits
• Maximum Sampling Rate: Upto 500 KS/s/ch
• Input Voltage Ranges: ±1 V, ±2 V, ±5 V, ±10 V
• Input Coupling: DC
• DAC: 8 Channels, Single-ended, voltage output
• Type of DAC: Enhanced R-2R
• DAC Resolution: 16 bits
• Maximum update rate: 1 MS/s/ch
• Output Voltage Range: ±10 V
• Output coupling: DC
• Digital Input/Output: 48 Channels, bi-directional
• I/O Compatibility: LVTTL, LVCMOS
• Logic family: Software-selectable.
Operating SystemLabVIEW Real-time OS
DimensionWithin 300 x 225 x 410 (W x H x D) in mm

ENVIRONMENTAL SPECIFICATIONS (ESS):

TestConditionRemark
Initial Visual/Physical Examination
Initial Functional tests
Random Vibrating (pre-thermal cycling test)Duration: 05 minutes for each axis.

Equipment: Energized Monitor important parameters during the test. Visual Examination after tests.
0.01 g2/Hz at 20 Hz to 0.01 g2/Hz at 40Hz

0.01 g2/Hz at 40Hz and dropping linearly to 0.0001 g2/Hz at 500Hz
Thermal CyclingEach Cycle consists of the following:
Temperature: -10°C to +55°C
Dwell time: 1 Hr
Rate of Changes:
1.5°C/min
No of Cycles: 10
Power ON
Random Vibrating (post thermal cycling test)Duration:05 minutes for each axis.

Equipment: Energized Monitor important parameters during the test. Visual Examination after tests.
0.01 g2/Hz at 20 Hz to 0.01 g2/Hz at 40Hz

0.02 g2/Hz at 40Hz and dropping linearly to 0.0001 g2/Hz at 500Hz

ENVIRONMENTAL SPECIFICATIONS (810G):

Test NameAcceptance Test Conditions
Random Vibration0.01 g2/Hz at 20 Hz to 0.01 g2/Hz at 40Hz
0.01 g2/Hz at 40Hz and dropping linearly to 0.01g2/Hz at 500 Hz
Duration: ½ Hr for each axis.
High-Temperature operation-cum-storageTemperature: +55°C (operational), +70°C (storage)
Duration: 4 Hrs
Low-Temperature operation-cum-storageTemperature: -20°C (operational), -40°C (storage)
Duration: 4 Hrs
Combined Altitude Temperature Humidity (CATH)15 min ramp to -20°C OFF
4 Hrs -20°C OFF
30 min ramp to Altitude 1km ON
30 min -10°C 1km ON
10 min ramp to Humidity 95%ON
30 min +43°C ON
15 min ramp to +55°C RH<30% ON
2 Hrs +55°C RH<30% ON
15 min altitude ramp RH<30% ON
4 Hrs +55°C RH<30% 1km ON
Fire Control System